Check the revision before replacing an N300V5-A
,en G-Energy N300V5-A is an air-cooled LED display power supply with a listed maximum output of 300 W. The store’s older figures and the downloadable V1.0 specification differ on several points. Compare both with the label and drawing for the unit you will receive.
| выхад | Listing: up to 300 W. V1.0: 5 V DC, 0–60 A, 300 W maximum, subject to derating. |
|---|---|
| Увод пераменнага току | Listing: 200–240 V AC. V1.0: 180–264 V AC. |
| Рабочая тэмп. | Listing: −30°C to +60°C. V1.0: −30°C to +50°C. |
| габарыт скрыні | Listing: 212 × 83 × 30, with no unit stated. V1.0: 212 × 81.5 × 30.5 mm. |
| Уваходная частата | 47–63 XNUMX Гц |
|---|---|
| Астуджэнне | паветранае астуджэнне |
| Каэфіцыент магутнасці | 0.50 пры 230 В пераменнага току |
| ток уцечкі | 0.30 мА пры 230 В пераменнага току |
| Тэмпература захоўвання. | ад −40°C да +100°C |
| Insulation tests | Input to output: 3.0 kV AC. Input to FG: 1.5 kV AC. Output to FG: 0.5 kV AC. |
| абарона | Паніжанае напружанне, перагрузка і кароткае замыканне |
| Пералічаныя стандарты | GB4943 and EN60950 |
Match the supplied unit to your cabinet
Check the full N300V5-A suffix, the mains range and the mounting holes. Use the derating data for the supplied revision to check the expected load at cabinet temperature. Power factor and leakage figures also differ between the original listing and V1.0. Ask for the revision’s own figures if those are part of your design requirements.
Агульныя пытанні
Can I use a 110 V supply?
110 V falls outside both the older 200–240 V listing and the 180–264 V V1.0 specification.
Which drawing should I use for the mounting plate?
Use the drawing for the supplied revision. The dimensions in the listing and in V1.0 differ.