Seven environmental readings over RS485
Jedno Huidu HD-S70 measures temperature, relative humidity, PM2.5, PM10, noise, atmospheric pressure and illuminance. It sends those readings over one RS485 Modbus RTU connection. Check which readings your LED controller can use before choosing the sensor.
Check the voltage before wiring. Huidu’s English V4.2 specification says 10–30 V DC. Its Chinese V4.3 specification says 5 V DC. Follow the label and instructions for the exact unit supplied.
| teplota | −40 až +120 °C |
|---|---|
| Vlhkost | 0–99% RV |
| PM2.5 a PM10 | 0–1,000 µg/m³ each, with 1 µg/m³ resolution |
| Hluk | 30–120 dB |
| tlak vzduchu | 0–120 kPa |
| Osvětlení | 0–200,000 luxů |
| Protokol | RS485 / Modbus RTU |
|---|---|
| Tovární nastavení | Address 0x01, 4,800 bit/s |
| Other baud rates | 2,400 nebo 9,600 bit/s |
| Vzdálenost kabelu | Up to 2,000 m in Huidu’s test. Actual reach depends on the cable and installation. |
Connect it to the controller
Check the RS485 interface and register map for each reading you want. If several devices share a bus, give each one a unique address and check A/B wiring. Use the specification for the supplied revision to confirm accuracy, response times and dimensions.
Běžné otázky
Does it measure wind speed or direction?
Huidu lists those readings for the HD-S90. The HD-S70 measures the seven values in the table above.
Will it work with my LED controller?
Check for RS485 Modbus RTU support and a compatible register map. Use the supply specified for the sensor revision.