LaitePower T400V5.0A1 for LED Signs
The LaitePower T400V5.0A1 is a 400W power supply with a single +5.0V DC output for LED displays. Its wide AC input range covers 90–264Vac. The unit uses a conformal-coated PCB and includes short-circuit and overcurrent protection.
Electrical Specifications
| Parameter | Specification |
|---|---|
| Output power | 400W |
| Rated output voltage | +5.0V DC |
| Output channel and current | CON2 (+)(−); 0–80A at 100–240Vac input |
| Input voltage range | 90Vac to 264Vac |
| Rated input voltage | 100Vac to 240Vac |
| Input frequency range | 47Hz to 63Hz |
| Rated input frequency | 50Hz to 60Hz |
| Input current at full load | Max. 5A at 100Vac; max. 2.8A at 240Vac |
| Inrush current, typical peak | 20A at 100Vac; 50A at 240Vac |
| Power factor | >0.98 at 100Vac; >0.95 at 230Vac |
| Efficiency at 100% load | >88.0% at 100Vac; >90.0% at 240Vac |
| Operating temperature | -10°C to +70°C |
| Startup temperature | -30°C |
| Protection functions | Short-circuit (SCP); overcurrent (OCP) |
| PCB treatment | Conformal coating |
Choosing the Correct Power Supply
Match the 5V output to the LED module specification, then check the required load, terminal arrangement and mounting drawing. The PDF includes derating curves; use these to assess the available output under the installation’s input voltage and ambient temperature.
Output data above comes from the linked T400V5.0A1 specification, version 1.1. Keep the full model suffix when comparing or ordering replacement units.
Product Photos



Download Specification
LaitePower T400V5.0A1 Specification
Frequently Asked Questions
What is the output of the T400V5.0A1?
The manufacturer specification lists a single +5.0V DC output, 400W power and a 0–80A current range at 100–240Vac input.
Can it operate on 110V or 230V AC?
Both voltages fall within its 90–264Vac input range. Review the PDF’s derating information for the planned load and input conditions.
What efficiency is specified?
At 100% load, the listed efficiency is greater than 88.0% at 100Vac and greater than 90.0% at 240Vac.
Is -30°C the continuous operating temperature?
No. The listing specifies -30°C startup and an operating range of -10°C to +70°C. Check the temperature derating curve before selecting a continuous load.
Where can I find the mounting and wiring information?
Download the original T400V5.0A1 specification above for the dimensions, installation drawing and connector definitions. The product photos are retained for visual identification.